Terms
Gap
No reading is received for several consecutive hours. A single missing reading is not counted. A gap is listed only when the number of consecutive missing readings reaches the threshold.
Stuck value
Several consecutive readings are identical, which can mean the sensor has stopped updating.
Spike
One reading rises or drops sharply, and the next reading returns to the previous level.
Level shift
Readings move to a different value range and stay in that range afterwards.
Out of range
A reading is above the upper limit or below the lower limit. The limits follow the equipment specification.
Rule file
Stores the on/off state and threshold of the five rules. After a change, the tool is run again and applies the new settings.
Original problem
Before
- Each quarter has dozens of sensors. Staff opened each time-series chart one by one, judged the anomalies and wrote the summary by hand.
- Anomaly judgements depended on individual experience, so different staff could judge and word the same chart differently.
- After the criteria changed, all charts had to be reviewed again.
After
- The tool retrieves one quarter of data from the database and classifies five anomaly types with explicit rules.
- Each anomaly type has a fixed sentence template, and the summary paragraph is built automatically with consistent wording.
- Thresholds are kept in the rule file. After an adjustment, the tool is run again and all sensors are processed with the same rules.
Workflow
Interactive demo: adjust the rules and view the summary
Outcome and technology
Explicit rules
The criteria and thresholds for the five anomaly types are written in the rule file. Running the same data again gives the same result.
Consistent wording
Each anomaly type has a fixed sentence template, so the summary text has the same format for every sensor and quarter.
Adjust and rerun
After the thresholds in the rule file are changed, the tool is run again and the charts, tables and summary text of all sensors are updated together.